N/A = No Information Available
DMP XT30 DSC Power 432 DSC PC1616 DSC PC1832 DSC Power 632 Ademco Vista-
10SE
Ademco Vista
15P
Napco
GEM-P816
Napco
GEM-P1632
GE Concord
Express
Bosch D2212B Bosch D4412
System Information
Areas
6 1 0 0 1 1 1 1 1 0 1 2
Partitions
1 1 2 4 1 1 1 1 1 1 1 1
Arming Systems
Area/All-Perim/
Home-Sleep-Away
Stay/Away No No Stay/Away Stay/Away Stay/Away Stay/Away Stay/Away Stay/Away N/A N/A
Remote Access Compatible
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Phone Cable Monitor
Yes Yes Yes Yes Yes No Ye s Ye s Ye s No Yes Ye s
Communication
Digital Dialer
SDLC, CID No SIA - CID SIA - CID No CID, Sescoa,
Standard Pulse
Formats
CID, 4X2, Sescoa/
Radionics
CID, SIA CID, SIA SIA, CID Modem IIIa2/4-2
(D2212) Modem IIIa2
(D2412)
Modem IIIa2/CID
E-Mail
On board Network
Communication
Allows for E-mail
Messages.
No No No No Requires "Total
Connect Service"
through Dealer
and Honeywell
plus additional
communications
module and service
through Honeywell
Requires "Total
Connect Service"
through Dealer
and Honeywell
plus additional
communications
module and service
through Honeywell
No No No No No
LAN/WAN Network Communications
Built-in No Yes TL 250 Yes TL 250 No AlarmNet module
required
AlarmNet module
required
Napco NetLink
Module, NL-MOD
Napco NetLink
Module, NL-MOD
No Dialer Capture
Module required
Dialer Capture
Module required
SMS TXT Messaging
Via 263C or 263H N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Cellular Support
CDMA or HSPA+ External Add on by
third party
External Add on by
third party
External Add on by
third party
External Add on by
third party
External Add on by
third party
External Add on by
third party
External Add on
"Starlink Cellular
Module"
External Add on
"Starlink Cellular
Module"
External Add on by
third party
External Add on by
third party
External Add on by
third party
Wireless Information
Wireless Arm/Disarm
Yes Yes Yes Yes Yes No Ye s Ye s Ye s Ye s Ye s Ye s
Wireless Types Supported
DMP 1100 Series-
Ademco - Inovonics
- ITI
DSC DSC 433mHz DSC 433mHz DSC Ademco Ademco Gemini Gemini ITI ITI DS
False Alarm Reduction Features
Exit Error
Yes Yes No No Yes Ye s Ye s Ye s Ye s Ye s No Yes
Fire Verify Zones
Yes Yes No No Yes Ye s Ye s Ye s Ye s Ye s Ye s Ye s
Cross Zoning
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Abort Reporting
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
System Test by User
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Ye s
System Recently Armed
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Programmable Entry/Exit Delays
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Transmit Delay
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Swinger Zone Bypassing
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Report Bypass to Central Station
Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Unique Duress Code
Yes Yes No No Yes Ye s Ye s Ye s Ye s Ye s Ye s Ye s
Call Waiting Cancel
Yes No No No No No No No No Yes No Yes
Compliance
California State Fire Marshal (CSFM)
Yes Yes Yes Yes Yes Yes Yes No No Yes Ye s Ye s
ANSI/UL 985 Household Fire Warning
Yes No Ye s Ye s No Yes Ye s No No Yes Yes Yes
ANSI/UL 1023 Household Burglar
Yes No No No No Ye s Ye s Ye s Ye s Ye s Ye s Ye s
ANSI/UL 1610 Central Station Burglar
Yes N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
ANSI/UL 1635 Digital Burglar
Yes No No No No No No No No No Yes Yes
SIA-CP-01-2010 False Alarm Reduction
Yes No Ye s Ye s No Yes (VISTA-10PSIA) No No No No No No
Made in U.S.A.
Yes No No No No No No No No No No No
DMP XT30 (continued)
DMP Product Comparisons Guide Digital Monitoring Products
4
COMPARISONS NOte
Kommentare zu diesen Handbüchern