N/A = No Information Available
DMP XTL Series
The DMP XTLC, XTLN, and XTLN-WiFi Systems operate via network or cellular communications. The XTL Series offers 30 user codes with authority levels, 28 wireless zones, and a 100-event memory. The XTL Series supports up to six areas, four two-way
wireless keypads and eight fobs.
Compares to:
DSC Alexsor, Power Series 9047
GE Interlogix Simon XT
Honeywell Lynx Plus,
Visonic Power Max Express, Power Max Pro
2GIG Technologies Go Control
DMP XTL Series DSC-Alexsor DSC-Power 9047 GE-Simon XT Honeywell
LYNX Plus
Visonic Power Max Express 2GIG Tech
Go Control
Zone Information
Maximum Wireless Zones
28 32 32 40 39 28 48
Control Panel Zones
0 No 2 2 1 1 2
Wireless Expansion Zones
28 32 32
38 if using 2 on-board zones
39 28 48
RF Operating Frequencies
905-924 MHz 433 MHz 433 MHz 319 MHz Bandwidth 350 kHz 345 MHz 315 MHz
(in USA & Canada)
433 MHz
Keypad/Access Information
Supervised Keypads
up to 4 DMP 9060/9063 Two-Way
wireless Keypads
up to 4 WT5500 2-way Wire-free
Keypads
No No 5828 and 5828V wireless keypads up to 8 non display wireless
keypads (Remote Commanders)
and 2 two-way keypads
4 Wireless2GIG-PAD1 Keypads
Built-in Keypad
No No Yes Yes Yes Yes Yes
Keypad back lighting turns red on alarm
Yes No No No No No No
Wireless Siren
Yes No No No Yes No Yes
Tamper
Yes Yes No No No No No
Enclosure / Panel Mounting
Wall Mount Wall Mount Wall Mount Wall Mount and desktop version Wall or optional desktop mounting Wall Mount Wall or optional desktop mounting
Standby Backup Power Rating
24 hours 24 hours No 24 hours 24 hours 12 hours 24 hours
User Information
User Codes/Access Cards
30 user codes with Master/
Standard Authority Levels
16 user codes 1 master code and 1
maintenance code
16 user codes 1 master code 1 Master code and 8 standard
codes
8 8 (4 digit user codes) 8
Event Memory
100 500 128 100 84 event log No No
Individual Zone Monitor
Yes Yes No Yes Yes Yes Yes
MyAccess™ Features
-Control via Cell Text Messages
Yes No No Yes Yes (optional) No Yes
-Email/Text Messages of System Activity
Yes No No Yes Yes (optional) No Yes
System Information
E-Mail
Yes No No Yes with optional GSM Module and
service
Requires Honeywell Total Connect
Subscription
No Yes
SMS TXT Messaging direct from the panel
Yes No No No No No No
Areas
6 No No No No 4 No
Arming Systems
Area/All-Perim/Home-Sleep-Away Stay/Away Stay/Away Stay/Away Stay/Away AWAY, HOME, AWAY-INSTANT, HOME-
INSTANT, LATCHKEY, FORCED,
BYPASS
Stay/Away
Communication formats
SDLC via cellular or network No No SIA or CID Ademco Express/Contact ID/
Ademco Low Speed/Radionic/
SESCOA 20PPS
SIA, Contact ID, SIA/IP No
Remote Downloadable
Cellular or network Yes Remote Yes Remote Yes Yes No Yes
Remote Control
Yes No Yes No Yes Yes Yes
Communication
Communications
Cellular or network Cell/Dialer Dialer Cell/Dialer Cell/Dialer Cell/Dialer Cell
Cellular Support
CDMA (XTLC) GSM/IP No GSM GSM Optional Built in GSM/GPRS
Communicator
GSM
DMP Product Comparisons Guide Digital Monitoring Products
1
COMPARISONS NOte
Kommentare zu diesen Handbüchern