5. PROGRAMMING
60
D-304762 PowerMaster-10/30 G2 Installer's Guide
Enter the "GSM/GPRS" menu, and press
to initiate the GSM diagnostic test. Upon test completion, the
PowerMaster will present the test result.
The following table presents the test result messages
Message Description
Unit is OK GSM / GPRS is functioning correctly
GSM comm. loss GSM/GPRS module does not communicate with the Panel
Pin code fail Missing or wrong PIN code. (Only if SIM card PIN code is enabled.)
GSM net. fail Unit failed with registration to local GSM network.
SIM card fail SIM not installed or SIM card failure.
GSM not detected GSM auto enroll failed to detect GSM/GPRS module.
No GPRS service The SIM card does not have the GPRS service enabled.
GPRS conn. fail Local GPRS network is not available or, wrong setting to GPRS APN, user and/or password.
Srvr unavailable PowerManage receiver cannot be reached – Check the Server IP
IP not defined Server IP #1 and #2 are not configured.
APN not defined APN is not configured.
SIM card locked After entering a wrong PIN code 3 consecutive times the SIM is locked. To unlock it enter a PUK
number. The PUK number cannot be entered by the control panel.
Denied by server PowerManage denies the connection request. Check that the panel is registered to PowerManage
5.9.4 Testing the SIM Number
1
The PowerMaster enables to test the SIM number to ensure the SIM number was entered correctly in the control panel
(see section 5.6.7) and to coordinate with the operator.
07:DIAGNOSTICS
SIM NUMBER TEST
Select IP RCVR#
Enter the "Select IP RCVR#" sub menu, select the IP server used for the verification of the SIM and press . The
panel sends a test SMS to the server.
If the server receives the SMS, the control panel will display “SIM# verifiedand the test ends successfully. If the SMS
was not received, for example, if there is no connection between the control panel and server, the control panel will
display “SIM not verified”.
5.9.5 Testing the Broadband/PowerLink Module
2, 3
The Broadband diagnostic procedure enables to test the communication of the Broadband Module (see section 5.6.8)
with the PowerManage server and reports the diagnostic result. In case of communication failure, detailed information
of the failure is reported.
07:DIAGNOSTICS
BROADBAND MODULE
PLEASE WAIT…
Unit is OK
Notes:
1. When the button is pressed, the test result may take up to 4 min. before it is displayed.
2. If the Broadband Module is not registered to the PowerMaster, the menu "BROADBAND MODULE" will not be
displayed.
The following table presents the list of messages that may be reported:
Message Description
Unit is ok Broadband Module is functioning correctly.
Test aborted The diagnostic test is aborted, as follows:
AC failure – Broadband Module is set to OFF mode.
Broadband Module has not completed the power-up procedure. In this case, the installer should
wait a maximum of 30 seconds before re-testing.
Comm. loss The RS-232 serial interface between the Broadband Module and the PowerMaster failed.
Rcvr Ip missing Receivers IP 1 and 2 settings are missing in the PowerMaster.
1
SIM number test is not applicable for UL installations
2
Broadband is not applicable for UL installations
3
The name of the product is PowerLink3 IP Communicator