5. PROGRAMMING
D-303222 PowerMaster-10/30 G2 Installer's Guide 49
Configuration Instructions
Note: For UL installations, the communication formats used are SIA and Contact ID and the
compatible receivers are the ones mentioned above.
Define the number of times the system will retry to report to the Monitoring Station in case of
failure to report via the PSTN telephone line connection.
Options: 2 attempts; 4 attempts (default); 8 attempts; 12 attempts and 16 attempts.
Note: For UL Listed product, set to "8 attempts".
Define the number of times the system will retry to report to the Monitoring Station in case of
failure to report via the cellular connection - GPRS (IP), GSM and SMS.
Options: 2 attempts; 4 attempts (default); 8 attempts; 12 attempts and 16 attempts.
Note: For UL Listed product, set to "8 attempts".
To verify a proper communication channel, the PowerMaster can be configured to send a test
event to the Monitoring Station via PSTN periodically. You can set the interval between the
consecutive test events or disable the automatic sending of this event entirely. If the interval is
set for every one day or more then the exact hour of reporting can be selected with option 52.
Options: test OFF (default); every 1/2/5/7/14/30 day(s); and every 5 hours.
Note: For UL Listed product, set to “every 1 day”.
Enter the exact time (auto test time) during the day at which the Auto Test message (if
enabled in option 51) will be sent to the Monitoring Station.
Note: If the AM/PM format is used, you can set the "AM" digit with the button and
the "PM" digit with the button.
53:COM.FAIL RPRT
PSTN FAIL
GSM/GPRS FAIL
(Return)
Determine whether a failure in any of the system communication channels i.e. PSTN or
GSM/GPRS will be reported or not and the time delay between detection of the failure and
reporting of the failure event to the Monitoring Station. A trouble event (i.e. "tel line fail" or
"GSM line fail") will be respectively stored in the event log.
Previously known as
"LINE FAIL REPORT"
Options "PSTN FAIL": immediat report (default); after 5/30/60/180 min; and do not report.
Options "GSM/GPRS FAIL": after 2/5/15/30 min and do not report (default).
False alarms may occur if users do not exit the premises within the exit delay period,
resulting in a false alarm a short time later. In such cases, inform the Monitoring Station that
the alarm occurred shortly after the system was armed (this event is known as "Recent
Close"). The report enabled option sends a “recent closing” report to the Monitoring Station if
an alarm occurs within 2 minutes from the end of the exit delay.
Options: report disabled (default) and report enabled
Notes:
1. CP-01 was tested and certified by ETL/Intertek.
2. CP-01 features not to be enabled in UL Listed product.
Some Monitoring Stations require that following an alarm event from a specific zone, the
system will also report when the alarming zone has restored to normal.
Options: report enabled (default) and report disabled
The PowerMaster can report a "System Inactive" event message (CID event 654) to the
Monitoring Station if the system is not used (i.e. armed) during a predefined time period.
Options: report disabled (default); after 7/14/30/90 days.
65:TWO WAY VOICE
1
Send 2wv code
You can configure the two way voice channel settings of the control panel
1
, as follows:
Send 2 WV Code: Define whether the system will send two-way voice code to the Monitoring
Refers to PowerMaster-30 G2 with voice option only