4 D-304046 TOWER-20 PG2 Installation Instructions
2.4. Configuring the Detector Parameters
Enter the menu and follow the configuration instructions for the TOWER-20 PG2 PIR detector as described below.
Option Configuration Instructions
Define whether or not to activate the alarm LED indication.
Optional settings: ON (default) and OFF.
Define if the detector operates at regular or high PIR sensitivity, or that at least one detection zone must be crossed
before an alarm is triggered (One Region).
Optional settings: LOW (default), HIGH and One Region.
Note: For EN compliance, the detector should be set to "One Region".
Define whether or not to set the activity time during Disarm mode.
Optional settings: NOT Active (default), YES – no delay, YES + 5s delay, YES + 15s delay, YES + 30s delay, YES +
1m delay, YES + 2m delay, YES + 5m delay, YES + 10m delay, YES + 20m delay and YES + 60m delay.
Enable or disable the outdoor anti-masking feature.
Optional settings: Disabled (default) and Enabled.
Define whether motion alarms are always enabled or only when dark (at night).
Optional settings: Day and Night (default) and Night only.
2.5 Local Diagnostic Test
A. Set the detector in local diagnostic mode, as follows:
Open the detector’s bottom cover (see Figure 4, steps 1 - 3) and then press and release the tamper switch (see Figure 5). The LED will flash
for 60 seconds and then the detector will enter into 15 minutes' local diagnostic mode.
Note: The detector automatically enters into 15 minutes' local diagnostic mode after battery installation or Tamper switch recovery.
B. Adjust the detector in the horizontal plane to cover the required protected area.
C. Walk into the detectors’ field of view. Adjust the vertical plane to receive the maximum number of detections when crossing the entire 90
pattern. Verify that the LED blinks each time your motion is detected, as you cross one Quad PIR. Then verify that the LED lights steadily
for 2 seconds as you cross the next adjacent Quad PIR. After alarm indication, the LED blinks three times and provides the received
signal strength indication (see Table 2).
Table 2 – Received Signal Strength Indication
LED response
Reception
Green LED blinks Strong
Orange LED blinks Good
Red LED blinks Poor
No blinks No communication
IMPORTANT! Reliable reception must be assured. Therefore, "poor" signal strength is not acceptable. If you receive a "poor" signal from the
detector, re-locate it and re-test until a "Good" or "Strong" signal strength is received.
Note: For detailed Diagnostics Test instructions refer to the control panel Installer's Guide
The LED blinking, described above, is operative only in Local diagnostic mode. Upon each full detection (LED lights steadily for 2 seconds), the
control panel receives the alarm. If required, perform the detector's horizontal / vertical adjustments (see section 2.1 and Figure 3).
Important! Instruct the user to perform a walk test at least once a week, to verify proper operation of the detector.
D. Place a piece of cardboard on the detector’s front side to deliberately mask the optical window. Verify that after 2 minutes, the yellow LED
lights continuously (see Table 3 below) and the alarm control panel receives the masking alarm.
E. Remove the masking from the detector’s front side. Verify that the LED turns off.
Table 3 - LED operation
LED Indications
Event
Red LED blinks Stabilization (warm-up 60 sec)
Red LED ON 0.2 sec. Tamper open / close
Red LED blinks twice One quad PIR detection in diagnostic mode
Red LED on 2 sec. Intruder alarm
Yellow LED on AM detection – diagnostic mode
Yellow LED blinks slowly (0.2 sec. ON, 30 sec. OFF) AM detection – Normal mode
Note: After detection, the detector disables itself to save battery power. It reverts to the ready state if there is no subsequent detection throughout
the following 2-minute period.
OUTDOOR ANTI-M
PIR SENSITIIVITY
ALARM Hours
DISARM ACTIVITY
ALARM LED