Important! Instruct the user to perform walk test at least once a
week, to verify proper operation of the detector.
C. Place a piece of cardboard on the detector’s front side, to
deliberately mask the optical window. After 2 minutes, the yellow
LED should light (see Table 3) and the alarm control panel should
receive the masking alarm.
D. Remove the masking from the detector’s front side. The LED
should extinguish (after about 30 seconds).
Table 3 – LED Operation
Event / status Indication
Low voltage Red flashing
Warm-up (60sec.) Yellow + Red flashing alternately
Self-test failure Yellow + Red flashing simultaneously
AM detection Yellow ON
ALARM Red ON for 2 sec.
Table 4 – Relay Outputs
Relay Output
Event / status
Trouble Alarm
Complete power failure Open Open
Standby Closed Closed
Low voltage Open Closed
Self-test failure Open Closed
AM detection DIP-SW4 = ON Open Open
AM detection DIP-SW4 = OFF Open Closed
Alarm Closed Open for 2 sec.
3.6 Cover Closure (see Fig. 4, steps 7 - 10)
31 2
Tamper switch
4
9
6
Bracket fastening (3 cable routing options)
Drill
Mark
5
For wall Tamper switch
7
Note
The 2 screw holes
enable adjustment
of the bracket on
the wall, if needed
as a result of the
walk test.
Fasten
(3 long screws)
Wiring
Press firmly
to release the
bracket
(2 short
screws)
24-HOUR
TAMPER
ZONE
12
VDC
ALARM CONTROL PANEL
BURGLAR
ZONE N.C.
TEST
SWITCH
(OPTION)
24 HOUR
TROUBLE
ZONE N.C.
DIP switches
1
2
3
4
OFF ON
SPARE
8
10
Figure 3 - Installation